Our central AC died. Does Mountain View make us install a heat pump instead?
On an existing single-family house, yes, if you replace it: since January 1, 2026, the reach code requires a heat pump when an air conditioner is replaced. You can still have the old unit repaired. A heat pump draws power much like the air conditioner it replaces, so the existing circuit usually works, though an electrician should confirm it.
Do we have to go to 200 amps to add an EV charger in Mountain View?
Only if the charger would exceed what your panel can carry. In that case the city accepts either an electrical load management system that keeps the total load within the panel's rating, or a panel upgrade, and an upgraded panel on a one-family house must be at least 200 amps under City Code Section 8.51(C).
Can I replace a breaker or an outlet without a permit?
Replacing a branch-circuit breaker with one of the required capacity in the same spot, and reinstalling a receptacle, are exempt. Adding a new outlet is not: Mountain View requires a permit for new receptacle outlets, and the new work must meet the arc-fault and ground-fault rules in the city's AFCI and GFCI guide.
We're putting a gas dryer in a remodeled laundry room. What does the 2026 code ask for?
The electrification reach code asks for pre-wiring for a future electric dryer in the remodeled area, so the switch later does not mean opening walls again. It does not require an electric dryer now. If that wiring alone would push the house into a panel upgrade, the code provides exceptions or alternative ways to comply.
Does the reach code force us to replace our gas water heater with an electric one?
No. The city's question-and-answer sheet on the 2025 reach codes says the heat pump requirement is triggered only by an air conditioner replacement and has nothing to do with water heating. If you choose a heat pump water heater anyway, the panel has to carry it, and the 200-amp minimum applies if it does not.